Support / Contact Us »
FAQ

|3/4/5 Port Solenoid Valves
How can I change N.C. valve type to N.O. type in the VP300/500/700 series?
For the body ported type, remove the end plate from the body and rotate the end plate by 180° and replace the plate on the body. For the base mounted type, remove the body from the sub-plate and position the "▼" mark of the body to the "N.O." mark of the sub-plate. (rotating the valve body 180°) In the refresh product of the base ported type (White colored body), 180°rotation is required not only to the valve body, but also to the end-plate for changing the valve types.