Support / Contact Us »
FAQ

|Air Cylinders
We were informed by supplier that a switch is not included with the CDQ2B20-10DZ-M9B. Why is this?
At 10 stroke using the D-M9B, the minimum stroke length required for the mounting of 2 auto-switches is not met. The M9B part numbers can be used from 15 stroke. The lead connection direction may differ, but by changing the end of the part number to M9BV, models can also be selected.
Minimum Stroke for Auto Switch Mounting