數位式壓力開關/感測器 (感測器・放大器一體型)
3畫面高精度數位式壓力開關 ISE7□/7□G/79S
・測定值可一邊觀看一邊設定
・IO-Link
・採用斜面的顯示部
確保各種安裝位置的辨識性
・採用顯示部迴轉機構
設置後可迴轉顯示部336°
・對應流體:空氣・非腐蝕性氣體・惰性氣體
(ISE70/71)
:不會腐蝕接流體部材質的液體或氣體(ISE7□G)
-
2D/3D CAD
能以各種數據格式輸出支持所有型號的2D/3D CAD數據。
能在安裝了選購件、歧管的狀態下輸出。
查看 2D/3D CAD
3畫面高精度數位式壓力開關 ISE7□/7□G/79S
說明書
Series |
Type |
查看搜尋結果 |
ISE70 | Positive pressure (For air) | 查看搜尋結果 |
ISE71 | Positive pressure (For air) | 查看搜尋結果 |
ISE70G | Positive pressure (For general fluids) | 查看搜尋結果 |
ISE75G | Positive pressure (For general fluids) | 查看搜尋結果 |
ISE76G | Positive pressure (For general fluids) | 查看搜尋結果 |
ISE77G | Positive pressure (For general fluids) | 查看搜尋結果 |
ISE78G | Positive pressure (For general fluids) | 查看搜尋結果 |
ISE79S | Positive pressure (For general fluids) | 查看搜尋結果 |
3畫面高精度數位式壓力開關 ISE7□/7□G/79S
自我宣告書
Series |
Type |
查看搜尋結果 |
ISE70 | Positive pressure (For air) | 查看搜尋結果 |
ISE71 | Positive pressure (For air) | 查看搜尋結果 |
ISE70G | Positive pressure (For general fluids) | |
ISE75G | Positive pressure (For general fluids) | |
ISE76G | Positive pressure (For general fluids) | |
ISE77G | Positive pressure (For general fluids) | |
ISE78G | Positive pressure (For general fluids) | |
ISE79S | Positive pressure (For general fluids) | |
Series | Type | Rated pressure range |
ISE70 | Positive pressure (For air) | 0 to 1MPa |
ISE71 | Positive pressure (For air) | 0 to 1.6MPa |
ISE70G | Positive pressure (For general fluids) | 0 to 1MPa |
ISE75G | Positive pressure (For general fluids) | 0 to 2MPa |
ISE76G | Positive pressure (For general fluids) | 0 to 5MPa |
ISE77G | Positive pressure (For general fluids) | 0 to 10MPa |
ISE78G | Positive pressure (For general fluids) | 0 to 16MPa |
ISE79S | Positive pressure (For general fluids) | 0 to 50MPa |
產品特點
■It is possible to change the settings while checking the measured value.
■Visualization of Settings
The sub screen (label) shows the item to be set.
■Angled display
Good visibility from various mounting positions
■Rotating display
■Simple 3-Step Setting
When the SET button is pressed and the set value (P_1) is being displayed, the set value (threshold value) can be set. When the SET button is pressed and the hysteresis value (H_1) is being displayed, the hysteresis value can be set.
■NPN/PNP Switch Function
Both NPN and PNP are available. The number of stock items can be reduced.
■Other Sub Screen Display
The peak value, bottom value, or both values can be displayed on one screen!
* Peak and bottom values are maintained even if the power supply is cut.
■Convenient Functions
■3 Setting Modes
Select the setting mode that best meets your needs.
■IO-Link Compatible
Visualization of operation and equipment status/Remote monitoring and control by communication
■Introduction of Series
■Select either the integrated type or the remote type according to the application.
■Application Examples