WEB Catalog
Product Information »
WEB Catalog
IN_PROD_498
»
Modular F.R.L./Pressure Control Equipment
IN_PROD_499
»
Modular F.R.L.


Product List
Subject ⁄ Industry Classified Products
Adobe Flash Player(v16 or later) is required to view the catalog.


Modular F.R.L.
Modular F.R.L. Units AC-D
![]() |
・Modular design with uniform body style
・Better visibility & environmental resistance ・2-layer construction: The bowl is covered with a transparent bowl guard! Better visibility: 360° ・No tools are required. Easier replacement of the element (AF-D only) ・Attachments: Spacer: Y200-D, Y300-D, Y400-D Spacer with bracket: Y200T-D, Y300T-D, Y400T-D |
Other Data |
---|
Description | Series | Port size |
---|---|---|
Air filter, Regulator, Lubricator |
AC20 to 60-D | 1/8,1/4,3/8,1/2,3/4,1 |
Filter regulator, Lubricator |
AC20A to 60A-D | 1/8,1/4,3/8,1/2,3/4,1 |
Air filter, Regulator | AC20B to 60B-D | 1/8,1/4,3/8,1/2,3/4,1 |
Air filter, Mist separator, Regulator |
AC20C to 40C-D | 1/8,1/4,3/8,1/2 |
Filter regulator, Mist separator |
AC20D to 40D-D | 1/8,1/4,3/8,1/2 |
Modular F.R.L. UnitsAC-D
Series | Download |
---|---|
AC20 to 60-D |
|
AC20A to 60A-D |
|
AC20B to 60B-D |
|
AC20C to 40C-D |
|
AC20D to 40D-D |
|
Air Filter AF-D
![]() |
・Better visibility & environmental resistance
2-layer construction: The bowl is covered with a transparent bowl guard! Better visibility: 360° ・No tools are required. Easier replacement of the element |
Other Data |
---|
Series | Port size | Filtration (μm) |
---|---|---|
AF20 to 60-D | 1/8,1/4,3/8,1/2,3/4,1 | 5 |
Air FilterAF-D
Series | Download |
---|---|
AF20 to 60-D |
|
Mist Separator AFM-D
![]() |
・Better visibility & environmental resistance
2-layer construction: The bowl is covered with a transparent bowl guard! Better visibility: 360° |
Other Data |
---|
Series | Port size | Filtration (μm) |
---|---|---|
AFM20 to 40-D | 1/8,1/4,3/8,1/2 | 0.3 |
Mist SeparatorAFM-D
Series | Download |
---|---|
AFM20 to 40-D |
|
Micro Mist Separator AFD-D
![]() |
・Better visibility & environmental resistance
2-layer construction: The bowl is covered with a transparent bowl guard! Better visibility: 360° |
Other Data |
---|
Series | Port size | Filtration (μm) |
---|---|---|
AFD20 to 40-D | 1/8,1/4,3/8,1/2 | 0.01 |
Micro Mist SeparatorAFD-D
Series | Download |
---|---|
AFD20 to 40-D |
|
Regulator AR-D
![]() |
・Easy to handle
Easy to hold when unlocked ・Selection of pressure gauges Square embedded type pressure gauge, Round type pressure gauge, Digital pressure switch ・Interchangeability is maintained. The mounting pitch for panel mounting is interchangeable with the AR(K)-B. The brackets and set nuts are the same for both existing and new products. |
Other Data |
---|
Series | Port size | Set pressure (MPa) |
---|---|---|
AR20 to 60-D | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
RegulatorAR-D
Series | Download |
---|---|
AR20 to 60-D |
|
Regulator with Backflow Function AR□K-D
![]() |
・The regulator with backflow function incorporates a mechanism that exhausts the
air pressure in the outlet side quickly. ・Easy to handle Easy to hold when unlocked ・Selection of pressure gauges Square embedded type pressure gauge, Round type pressure gauge, Digital pressure switch ・Interchangeability is maintained. The mounting pitch for panel mounting is interchangeable with the AR(K)-B. The brackets and set nuts are the same for both existing and new products. |
Other Data |
---|
Series | Port size | Set pressure (MPa) |
---|---|---|
AR20K to 60K-D | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
Regulator with Backflow FunctionAR□K-D
Series | Download |
---|---|
AR20K to 60K-D |
|
Modular Type Common Supply Regulator AR□M(K)-D
![]() |
・Supply different pressure for multiple applications
OUT port is on the back of the product. ・Space-saving design and reduced piping labor ・Modular connection is possible. ・Branch piping |
Other Data |
---|
Series | Port size | Set pressure (MPa) |
---|---|---|
AR20M-D to AR40M-D | 1/8,1/4,3/8,1/2 |
0.05 to 0.85 0.02 to 0.2 |
AR20MK-D to AR40MK-D With backflow function |
1/8,1/4,3/8,1/2 |
0.1 to 0.85 0.1 to 0.2 |
Modular Type Common Supply RegulatorAR□M(K)-D
Series | Download |
---|---|
AR20M-D to AR40M-D |
|
AR20MK-D to AR40MK-D With backflow function |
|
Lubricator AL-D
![]() |
・Better visibility & environmental resistance
2-layer construction: The bowl is covered with a transparent bowl guard! Better visibility: 360° |
Other Data |
---|
Series | Port size | Oil capacity (cm3) |
---|---|---|
AL20 to 60-D | 1/8,1/4,3/8,1/2,3/4,1 | 25 to 135 |
LubricatorAL-D
Series | Download |
---|---|
AL20 to 60-D |
|
Filter Regulator AW-D
![]() |
・Integrated filter and regulator units save space and require less piping.
・Easy to handle Easy to hold when unlocked ・Better visibility & environmental resistance 2-layer construction: The bowl is covered with a transparent bowl guard! Better visibility: 360° ・Interchangeability is maintained. The mounting pitch for panel mounting is interchangeable with the AW(K)-B. The brackets and set nuts are the same for both existing and new products. |
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AW20 to 60-D | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
5 |
Filter RegulatorAW-D
Series | Download |
---|---|
AW20 to 60-D |
|
Regulator with Backflow Function AW□K-D
![]() |
・Integrated filter and regulator units save space and require less piping.
・The regulator with backflow function incorporates a mechanism that exhausts the air pressure in the outlet side quickly. ・Easy to handle Easy to hold when unlocked ・Better visibility & environmental resistance 2-layer construction: The bowl is covered with a transparent bowl guard! Better visibility: 360° ・Interchangeability is maintained. The mounting pitch for panel mounting is interchangeable with the AW(K)-B. The brackets and set nuts are the same for both existing and new products. |
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AW20K to 60K-D | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
5 |
Regulator with Backflow FunctionAW□K-D
Series | Download |
---|---|
AW20K to 60K-D |
|
Modular F.R.L. Units AC-A
![]() |
・Easy element replacement
The element and the bowl are integrated. Replacement can be done in hand. ・Energy-saving regulator Pressure drop: Max. 50% improvement ・Reduced required maintenance space: Max. 46% reduction ・Better visibility & increased safety The bowl is covered with a transparent bowl guard. ・Attachments: Spacer: Y200-A, Y300-A, Y400-A, Y500-A Spacer with bracket: Y200T-A, Y300T-A, Y400T-A, Y500T-A |
Other Data |
---|
Combination equipment | Series | Port size | Set pressure (MPa) |
---|---|---|---|
Air filter, Regulator, Lubricator |
AC10 to 40-A | M5,1/8,1/4,3/8,1/2,3/4 |
0.05 to 0.7 0.02 to 0.2 |
Filter regulator, Lubricator |
AC10A to 40A-A | M5,1/8,1/4,3/8,1/2,3/4 |
0.05 to 0.7 0.02 to 0.2 |
Air filter, Regulator | AC10B to 40B-A | M5,1/8,1/4,3/8,1/2,3/4 |
0.05 to 0.7 0.02 to 0.2 |
Air filter, Mist separator, Regulator |
AC20C to 40C-A | 1/8,1/4,3/8,1/2,3/4 |
0.05 to 0.7 0.02 to 0.2 |
Filter regulator, Mist separator |
AC20D to 40D-A | 1/8,1/4,3/8,1/2,3/4 |
0.05 to 0.7 0.02 to 0.2 |
Modular F.R.L. UnitsAC-A
Series | Download |
---|---|
AC10 to 40-A |
|
AC10A to 40A-A |
|
AC10B to 40B-A |
|
AC20C to 40C-A |
|
AC20D to 40D-A |
|
Air Filter AF-A
![]() |
・Easy element replacement
The element and the bowl are integrated. Replacement can be done in hand. ・Reduced required maintenance space: Max. 46% reduction ・Better visibility & increased safety The bowl is covered with a transparent bowl guard. |
Other Data |
---|
Series | Port size | Filtration (μm) |
---|---|---|
AF10 to 60-A | M5,1/8,1/4,3/8,1/2,3/4,1 | 5 |
Air FilterAF-A
Series | Download |
---|---|
AF10 to 60-A |
|
Mist Separator AFM-A
![]() |
・Better visibility & increased safety
The bowl is covered with a transparent bowl guard. |
Other Data |
---|
Series | Port size | Filtration (μm) |
---|---|---|
AFM20 to 40-A | 1/8,1/4,3/8,1/2,3/4 | 0.3 |
Mist SeparatorAFM-A
Series | Download |
---|---|
AFM20 to 40-A |
|
Micro Mist Separator AFD-A
![]() |
・Better visibility & increased safety
The bowl is covered with a transparent bowl guard. |
Other Data |
---|
Series | Port size | Filtration (μm) |
---|---|---|
AFD20 to 40-A | 1/8,1/4,3/8,1/2,3/4 | 0.01 |
Micro Mist SeparatorAFD-A
Series | Download |
---|---|
AFD20 to 40-A |
|
Regulator AR-A
![]() |
・Energy-saving regulator Pressure drop: Max. 50% improvement
|
Other Data |
---|
Series | Port size | Set pressure (MPa) |
---|---|---|
AR10 to 40-A | M5,1/8,1/4,3/8,1/2,3/4 |
0.05 to 0.7 0.02 to 0.2 |
RegulatorAR-A
Series | Download |
---|---|
AR10 to 40-A |
|
Lubricator AL-A
![]() |
・Better visibility & increased safety
The bowl is covered with a transparent bowl guard. ・Semi-standard specifications: 1000 cm3 tank (AL30 to AL60) |
Other Data |
---|
Series | Port size | Bowl capacity (cm3) |
---|---|---|
AL10 to 60-A | M5,1/8,1/4,3/8,1/2,3/4,1 | 7 to 135 |
LubricatorAL-A
Series | Download |
---|---|
AL10 to 60-A |
|
Filter Regulator AW-A
![]() |
・Easy element replacement
The element and the bowl are integrated. Replacement can be done in hand. ・Energy-saving regulator Pressure drop: Max. 50% improvement ・Reduced required maintenance space: Max. 46% reduction ・Better visibility & increased safety The bowl is covered with a transparent bowl guard. |
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AW10 to 40-A | M5,1/8,1/4,3/8,1/2,3/4 |
0.05 to 0.7 0.02 to 0.2 |
5 |
Filter RegulatorAW-A
Series | Download |
---|---|
AW10 to 40-A |
|
Modular F.R.L. Units AC-B
![]() |
・Better visibility and environmental resistance
・Easy element replacement The element and the bowl are integrated. Replacement can be done in hand. ・Reduced required maintenance space: Max. 46% reduction ・Regulator: Set pressure 0.05 to 0.85 MPa, 0.02 to 0.2 MPa ・Choose from a selection of pressure gauges: Square embedded type pressure gauge, Round type pressure gauge, Digital pressure switch |
Other Data |
---|
Combination equipment | Series | Port size | Set pressure (MPa) |
---|---|---|---|
Air filter, Regulator, Lubricator | AC20 to 60-B | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
Filter regulator, Lubricator | AC20A to 60A-B | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
Air filter, Regulator | AC20B to 60B-B | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
Air filter, Mist separator, Regulator | AC20C to 40C-B | 1/8,1/4,3/8,1/2,3/4 |
0.05 to 0.85 0.02 to 0.2 |
Filter regulator, Mist separator | AC20D to 40D-B | 1/8,1/4,3/8,1/2,3/4 |
0.05 to 0.85 0.02 to 0.2 |
Modular F.R.L. UnitsAC-B
Series | Download |
---|---|
AC20 to 60-B |
|
AC20A to 60A-B |
|
AC20B to 60B-B |
|
AC20C to 40C-B |
|
AC20D to 40D-B |
|
Regulator AR-B
![]() |
|
Other Data |
---|
Series | Port size | Set pressure (MPa) |
---|---|---|
AR20 to 60-B | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
RegulatorAR-B
Series | Download |
---|---|
AR20 to 60-B |
|
High Pressure: Made to Order AR20 to 60-B-X425
![]() |
Stronger materials are used for the manufacturing of regulators intended for
high-pressure operation. The modified construction also allows for a wider set pressure range. Refer to the AR series made to order specifications in the AC series catalog for details. ▶Click here for details |
|
Other Data |
---|
Series | Proof pressure [MPa] | Max. operationg pressure [MPa] | Set pressure range [MPa] | Ambient and fluid temperatures [℃] |
---|---|---|---|---|
AR20 to 60-B-X425 | 3.0 | 2.0 | 0.1 to 1.7 | -5 to 60 (No freezing) |
High Pressure: Made to OrderAR20 to 60-B-X425
Series | Download |
---|---|
AR20 to 60-B-X425 |
|
Regulator with Backflow Function AR□K-B
![]() |
・The regulator with backflow function incorporates a mechanism
that exhausts the air pressure in the outlet side quickly. |
Other Data |
---|
Series | Port size | Set pressure (MPa) |
---|---|---|
AR20K to 60K-B | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
Regulator with Backflow FunctionAR□K-B
Series | Download |
---|---|
AR20K to 60K-B |
|
Filter Regulator AW-B
![]() |
|
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AW20 to 60-B | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
5 |
Filter RegulatorAW-B
Series | Download |
---|---|
AW20 to 60-B |
|
Filter Regulator with Backflow Function AW□K-B
![]() |
・Integrated filter and regulator units save space and require less piping.
・The filter regulator with backflow function incorporates a mechanism that exhausts the air pressure in the outlet side quickly. |
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AW20K to 60K-B | 1/8,1/4,3/8,1/2,3/4,1 |
0.05 to 0.85 0.02 to 0.2 |
5 |
Filter Regulator with Backflow FunctionAW□K-B
Series | Download |
---|---|
AW20K to 60K-B |
|
Filter Regulator AW30/40-X2622
![]() |
・Stainless steel 316 and special temperature environment (−40℃) specifications
・Material of external parts: Stainless steel 316 ・Ambient and fluid temperatures: −40 to 80℃ ・NACE International Standards compliant |
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AW30/40-X2622 | 1/4,3/8,1/2,3/4 | 0.05 to 0.85 | 5 |
Filter RegulatorAW30/40-X2622
Series | Download |
---|---|
AW30/40-X2622 |
|
Mist Separator Regulator AWM
![]() |
|
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AWM20 to 40 | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 | 0.3 |
Mist Separator RegulatorAWM
Series | Download |
---|---|
AWM20 to 40 |
|
Micro Mist Separator Regulator AWD
![]() |
|
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AWD20 to 40 | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 | 0.01 |
Micro Mist Separator RegulatorAWD
Series | Download |
---|---|
AWD20 to 40 |
|
Modular F.R.L. Units ACG-B
![]() |
・Improved visibility by mounting the pressure gauge on the top of the knob
・Transparent bowl guard Improved environmental durability due to 2-layer construction (Body size 30 or more) Better visibility: 360º Light weight: Approx. 12% reduction |
Other Data |
---|
Combination equipment | Series | Port size | Set pressure (MPa) |
---|---|---|---|
Air filter, Regulator with built-in pressure gauge, Lubricator |
ACG20 to 40-B | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Filter regulator with built-in pressure gauge, Lubricator |
ACG20A to 40A-B | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Air filter, regulator with built-in pressure gauge |
ACG20B to 40B-B | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Air filter, mist separator, regulator with built-in pressure gauge |
ACG20C to 40C-B | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Filter regulator with built-in pressure gauge, Mist separator |
ACG20D to 40D-B | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Modular F.R.L. UnitsACG-B
Series | Download |
---|---|
ACG20 to 40-B |
|
ACG20A to 40A-B |
|
ACG20B to 40B-B |
|
ACG20C to 40C-B |
|
ACG20D to 40D-B |
|
Regulator with Built-in Pressure Gauge ARG-B
![]() |
・Improved visibility by mounting the pressure gauge on the top of the knob
|
Other Data |
---|
Series | Port size | Set pressure (MPa) |
---|---|---|
ARG20 to 40-B | 1/8,1/4,3/8,1/2 | 0.02 to 0.2 |
Regulator with Built-in Pressure GaugeARG-B
Series | Download |
---|---|
ARG20 to 40-B |
|
Regulator with Built-in Pressure Gauge with Backflow Function
ARG□K-B
ARG□K-B
![]() |
・Improved visibility by mounting the pressure gauge on the top of the knob
|
Other Data |
---|
Series | Port size | Set pressure (MPa) |
---|---|---|
ARG20K to 40K-B | 1/8,1/4,3/8,1/2 |
0.05 to 0.85 0.02 to 0.2 |
Regulator with Built-in Pressure Gauge with Backflow Function
ARG□K-B
ARG□K-B
Series | Download |
---|---|
ARG20K to 40K-B |
|
Filter Regulator with Built-in Pressure Gauge AWG-B
![]() |
・Improved visibility by mounting the pressure gauge on the top of the knob
・Transparent bowl guard Improved environmental durability due to 2-layer construction (Body size 30 or more) Better visibility: 360º, Lightweight: Approx. 12% reduction |
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AWG20 to 40-B | 1/8,1/4,3/8,1/2 |
0.05 to 0.85 0.02 to 0.2 |
5 |
Filter Regulator with Built-in Pressure GaugeAWG-B
Series | Download |
---|---|
AWG20 to 40-B |
|
Filter Regulator with Built-in Pressure Gauge with Backflow Function
AWG□K-B
AWG□K-B
![]() |
・Improved visibility by mounting the pressure gauge on the top of the knob
・Transparent bowl guard Improved environmental durability due to 2-layer construction (Body size 30 or more) Better visibility: 360º, Lightweight: Approx. 12% reduction |
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AWG20K to 40K-B | 1/8,1/4,3/8,1/2 |
0.05 to 0.85 0.02 to 0.2 |
5 |
Filter Regulator with Built-in Pressure Gauge with Backflow Function
AWG□K-B
AWG□K-B
Series | Download |
---|---|
AWG20K to 40K-B |
|
Modular Type F.R.L. Unit ACG
![]() |
・Improves the visibility of pressure gauges located in various locations
∗ The ACG series will be remodeled in May 2021. Please select the ACG-B series. |
Other Data |
---|
Combination equipment | Series | Port size | Set pressure (MPa) |
---|---|---|---|
Air filter, Regulator with built-in pressure gauge, Lubricator |
ACG20 to 40 | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Filter regulator with built-in pressure gauge, Lubricator |
ACG20A to 40A | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Air filter, Regulator with built-in pressure gauge |
ACG20B to 40B | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Air filter, Mist separator, Regulator with built-in pressure gauge |
ACG20C to 40C | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Filter regulator with built-in pressure gauge, Mist separator |
ACG20D to 40D | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Modular Type F.R.L. UnitACG
Series | Download |
---|---|
ACG20 to 40 |
|
ACG20A to 40A |
|
ACG20B to 40B |
|
ACG20C to 40C |
|
ACG20D to 40D |
|
Regulator with Built-in Pressure Gauge ARG
![]() |
・Improves the visibility of pressure gauges located in various locations
∗ The ARG series will be remodeled in May 2021. Please select the ARG-B series. |
Other Data |
---|
Series | Port size | Set pressure (MPa) |
---|---|---|
ARG20 to 40 | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Regulator with Built-in Pressure GaugeARG
Series | Download |
---|---|
ARG20 to 40 |
|
Regulator with Built-in Pressure Gauge with Backflow Function ARG□K
![]() |
・Improves the visibility of pressure gauges located in various locations
∗ The ARG□K series will be remodeled in May 2021. Please select the ARG□K-B series. |
Other Data |
---|
Series | Port size | Set pressure (MPa) |
---|---|---|
ARG20K to 40K | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 |
Regulator with Built-in Pressure Gauge with Backflow FunctionARG□K
Series | Download |
---|---|
ARG20K to 40K |
|
Filter Regulator with Built-in Pressure Gauge AWG
![]() |
・Improves the visibility of pressure gauges located in various locations
∗ The AWG series will be remodeled in May 2021. Please select the AWG-B series. |
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AWG20 to 40 | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 | 5 |
Filter Regulator with Built-in Pressure GaugeAWG
Series | Download |
---|---|
AWG20 to 40 |
|
Filter Regulator with Built-in Pressure Gauge with Backflow Function AWG□K
![]() |
・Improves the visibility of pressure gauges located in various locations
∗ The AWG□K series will be remodeled in May 2021. Please select the AWG□K-B series. |
Other Data |
---|
Series | Port size | Set pressure (MPa) | Filtration (μm) |
---|---|---|---|
AWG20K to 40K | 1/8,1/4,3/8,1/2 | 0.05 to 0.85 | 5 |
Filter Regulator with Built-in Pressure Gauge with Backflow FunctionAWG□K
Series | Download |
---|---|
AWG20K to 40K |
|
Modular Adapter E210/310/410
![]() |
・Can be easily connected to current products
・Can be freely rotated, thus allowing a wide selection of mounting directions ・Can be connected to current products of different sizes ・Reduced required space/piping maintenance costs |
Other Data |
---|
Series | Port size | Applicable products |
---|---|---|
E210 | 1/8,1/4 |
Modular F.R.L. equipment (Filters, regulators, lubricators, etc.) 2-port solenoid valve 3-port solenoid valve |
E310 | 1/4, 3/8 |
Modular F.R.L. equipment (Filters, regulators, lubricators, etc.) 2-port solenoid valve 3-port solenoid valve |
E410 | 1/4, 3/8, 1/2 |
Modular F.R.L. equipment (Filters, regulators, lubricators, etc.) 2-port solenoid valve 3-port solenoid valve |
Modular AdapterE210/310/410
Series | Download |
---|---|
E210 |
|
E310 |
|
E410 |
|
Conforming to OSHA Standard: Pressure Relief 3 Port Valve with Locking Holes VHS
![]() |
・Compliant with OSHA Standards (Occupational Safety and Health
Administration Department of Labor) ・This manually operated valve can be used to prevent accidents caused by residual pressure in pneumatic lines. ・The supply and exhaust status of air flow can be confirmed at a glance. ・When in the exhaust position, the valve may be padlock secured. This can prevent accidental start-ups while personnel are cleaning or servicing equipment. ・Push the knob and then turn. This 2-step action can prevent malfunctions. |
Other Data |
---|
Series | Description | Knob operation | Port size |
---|---|---|---|
VHS20 |
Pressure relief 3-port valve with locking holes |
Single action | 1/8,1/4 |
VHS30 |
Pressure relief 3-port valve with locking holes |
Single action | 1/4,3/8 |
VHS40 |
Pressure relief 3-port valve with locking holes |
Single action | 1/4,3/8,1/2,3/4 |
VHS50 |
Pressure relief 3-port valve with locking holes |
Single action | 3/4,1 |
VHS2510 |
Pressure relief 3-port valve with locking holes |
Double action | 1/8,1/4 |
VHS3510 |
Pressure relief 3-port valve with locking holes |
Double action | 1/4,3/8 |
VHS4510 |
Pressure relief 3-port valve with locking holes |
Double action | 1/4,3/8,1/2,3/4 |
VHS5510 |
Pressure relief 3-port valve with locking holes |
Double action | 3/4,1 |
Conforming to OSHA Standard: Pressure Relief 3 Port Valve with Locking HolesVHS
Series | Download |
---|---|
VHS20 |
|
VHS30 |
|
VHS40 |
|
VHS50 |
|
VHS2510 |
|
VHS3510 |
|
VHS4510 |
|
VHS5510 |
|
Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve VP500/700
![]() |
・For connecting to F.R.L. units
・Allows for space saving and reduced piping labor ・Power consumption: 0.35 W (Without light) |
Other Data |
---|
Series | Applicable combinations |
---|---|
VP500 | AC25-A,AC30-A |
VP700 | AC40-A |
Modular Connection Type Residual Pressure Relief 3 Port Solenoid ValveVP500/700
Series | Download |
---|---|
VP500 |
|
VP700 |
|
Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A
![]() |
・Start-up valve for low-speed air supply to gradually raise
the initial pressure in an air system and for quick exhaust by cutting off the air supply ・Power consumption: 0.35 W ・Improved flow rate characteristics: Up to 2.3 times that of the existing model C [dm3/(s·bar)]: 9.2 ・Energy saving: No air flow when the main valve is switched ・Improved adjustability at low-speed air supply ・Smaller profile and reduced labor due to integrated silencer |
Other Data |
---|
Series | C [dm3/(s・bar)] |
Port size | Operating pressure range (MPa) |
---|---|---|---|
AV2000-A | 9.2 | 1/4 | 0.2 to 1.0 |
AV3000-A | 13.1 | 3/8 | 0.2 to 1.0 |
AV4000-A | 19.2 | 1/2 | 0.2 to 1.0 |
AV5000-A |
34.8 41.3 |
3/4 1 |
0.2 to 1.0 |
Soft Start-up ValveAV2000-A/3000-A/4000-A/5000-A
Series | Download |
---|---|
AV2000-A |
|
AV3000-A |
|
AV4000-A |
|
AV5000-A |
|
Soft Start-up Valve AV
![]() |
・A starting valve that can supply air at a low speed and exhaust it at a
high speed by blocking the air supply |
Other Data |
---|
Series | Port size | Operating pressure (MPa) |
---|---|---|
AV2000 to 5000 | 1/4,3/8,1/2 | 0.1 to 1 |
Soft Start-up ValveAV
Series | Download |
---|---|
AV2000 to 5000 |
|
Large Flow Air Filter AF
![]() |
|
Other Data |
---|
Series | Port size | Filtration (μm) |
---|---|---|
AF800/900 | 1 1/4,1 1/2,2 | 5 |
Large Flow Air FilterAF
Series | Download |
---|---|
AF800/900 |
|
マイリストに追加