WEB Catalog
Product Information »
WEB Catalog
IN_PROD_449
»
Directional Control Valves
IN_PROD_453
»
Reduced-wiring Fieldbus System (Serial Transmission System)


Product List
Subject ⁄ Industry Classified Products
Adobe Flash Player(v16 or later) is required to view the catalog.


Reduced-wiring Fieldbus System (Serial Transmission System)
Serial Transmission System EX120/121/122/123/124/126/140/180
![]() |
For Output
∗The applicable protocols differ depending on the series. For details, refer to the catalog of each series. ∗The NKE Corp. Fieldbus H System was discontinued in February 2021. Please consider switching to a different network. |
Other Data |
---|
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX120 | IP20 |
DeviceNet™ CC-Link CompoNet™ CompoBus/S NKE (Wiring saving system) S-LINK V (Made to order) |
JSY1000, 3000, 5000 (Plug-in) SY3000,5000,7000 (Plug-in) VQ1000,2000 SV1000,2000,3000,4000 |
EX121 | IP20 |
DeviceNet™ CC-Link CompoNet™ CompoBus/S NKE (Wiring saving system) S-LINK V (Made to order) |
SY3000,5000 |
EX122 | IP20 |
DeviceNet™ CC-Link CompoNet™ CompoBus/S NKE (Wiring saving system) S-LINK V (Made to order) |
SY3000,5000 |
EX123 | IP65 | NKE (Wiring saving system) | VQ2000,4000,5000 |
EX124 | IP65 |
CC-Link CompoBus/S DeviceNet™ (Made to order) |
VQ2000,4000,5000 |
EX126 | IP67 | CC-Link |
SY3000,5000,7000 (Plug-in) SV1000,2000,3000 VQC1000,2000,4000, 5000 |
EX140 | IP20 |
DeviceNet™ CC-Link CompoBus/S NKE(Wiring saving system) |
SZ3000 SQ1000,2000 |
EX180 | IP20 |
DeviceNet™ CC-Link EtherCAT (Made to order) AnyWireASLINK (Made to order) |
SY3000,5000,7000 SJ2000,3000 S0700 |
Serial Transmission SystemEX120/121/122/123/124/126/140/180
Series | Download |
---|---|
EX120 |
|
EX121 |
|
EX122 |
|
EX123 |
|
EX124 |
|
EX126 |
|
EX140 |
|
EX180 |
|
Serial Transmission System EX260
![]() |
For Output
∗The applicable protocols differ depending on the series. For details, refer to the catalog of each series. ・IP67 ・RJ45 communication connectors (X205) |
Other Data |
---|
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX260 | IP67 |
DeviceNet™ PROFIBUS DP CC-Link EtherCAT PROFINET EtherNet/IP™ Ethernet POWERLINK IO-Link (Only available for SY, JSY, VQC communication connectors) |
SY3000,5000,7000 (Plug-in) JSY1000,3000,5000 (Plug-in) VQC1000,2000,4000,5000 SV1000,2000,3000 S0700(IP40) |
Serial Transmission SystemEX260
Series | Download |
---|---|
EX260 |
|
Power Block EX9-PE1-X15/X22/X23/X24
![]() |
・Power can be supplied individually to 8 power
supply systems using up to 4 power blocks. Different areas on the same manifold can be controlled by separate-system power supplies. Contributes to the reduction of installation space ・Maximum number of outputs: 32 ・IP67 compliant (Manifold assembly) |
Other Data |
---|
Series | Applicable valve |
---|---|
EX9-PE1-X15/X22/X23/X24 | JSY,SY,VQC,S0700,SV |
Power BlockEX9-PE1-X15/X22/X23/X24
Series | Download |
---|---|
EX9-PE1-X15/X22/X23/X24 |
|
Serial Transmission System EX250
![]() |
For Input/Output
∗The applicable protocols differ depending on the series. For details, refer to the catalog of each series. |
Other Data |
---|
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX250 | IP67 |
DeviceNet™ PROFIBUS DP CC-Link AS-Interface CANopen EtherNet/IP™ |
JSY1000, 3000, 5000 (Plug-in) SY3000,5000,7000 (Plug-in) VQC1000,2000,4000,5000 SV1000,2000,3000 S0700(IP40) |
Serial Transmission SystemEX250
Series | Download |
---|---|
EX250 |
|
Fieldbus System EX245
![]() |
・A PROFIsafe compatible product has been added. [New]
・For Input/Output ・Push Pull connectors AIDA specifications compliant SCRJ connectors, RJ45 connectors ・Compatible with the PROFIenergy energy-saving function ・Shared Device function |
Other Data |
---|
Series | Enclosure | Communication protocol | Applicable valve |
---|---|---|---|
EX245 | IP65 |
PROFINET PROFIsafe |
JSY3000, 5000 (Plug-in) SY3000, 5000 (Plug-in) VQC2000, 4000 |
Fieldbus SystemEX245
Series | Download |
---|---|
EX245 |
|
Fieldbus System EX245
![]() |
・For Input/Output
・AIDA∗ specifications compliant ∗ Abbreviation of the Automation Initiative of German (Deutschland) Automobile Manufacturers ・Push Pull connectors One-touch installation and removal Reduced wiring time ・Modules can be combined flexibly. |
Other Data |
---|
Series | Enclosure | Communication protocol | Applicable valve |
---|---|---|---|
EX245 | IP65 |
PROFINET INTERBUS (Made to order) PROFIBUS DP (Made to order) |
SY3000, 5000, 7000 (Plug-in) VQC1000, 2000, 4000, 5000 SV1000, 2000, 3000 |
Fieldbus SystemEX245
Series | Download |
---|---|
EX245 |
|
Serial Transmission System EX600
![]() |
For Input/Output
∗The applicable protocols differ depending on the series. For details, refer to the catalog of each series. |
Other Data |
---|
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX600 | IP67 |
PROFIBUS DP DeviceNet™ CC-Link EtherNet/IP™ EtherCAT PROFINET PROFINET (IO-Link master compatible) MRP (PROFINET) (Made to order) Ethernet POWERLINK (Made to order) Modbus TCP (Made to order) CC-Link IE Field (Made to order) EtherNet/IP™ (IO-Link master compatible) (Made to order) |
JSY1000, 3000, 5000 (Plug-in) SY3000,5000,7000 (Plug-in) SV1000,2000,3000 VQC1000,2000,4000,5000 S0700(IP40) |
Serial Transmission SystemEX600
Series | Download |
---|---|
EX600 |
|
CC-Link IE Field Compatible Fieldbus System EX600-SCF1-X60
![]() |
・Supports the CC-Link IE Field communication protocol
|
Other Data |
---|
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX600-SCF1-X60 |
IP67 (Manifold assembly) |
CC-Link IE Field |
SY3000, 5000, 7000 (Plug-in) JSY1000, 3000, 5000 VQC1000, 2000, 4000, 5000 SV1000, 2000, 3000 S0700 |
CC-Link IE Field Compatible Fieldbus SystemEX600-SCF1-X60
Series | Download |
---|---|
EX600-SCF1-X60 |
|
Serial Transmission System EX500
![]() |
For Input/Output, Gateway Type
∗The applicable protocols differ depending on the series. For details, refer to the catalog of each series. ∗ The EX500-GDN1 series was discontinued in March 2021. Please select the EX260-SDN series, EX600-SDN series. |
Other Data |
---|
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX500 | IP67 |
EtherNet/IP™ PROFINET DeviceNet™ PROFIBUS DP |
SY3000,5000,7000 (Plug-in) VQC1000,2000,4000,5000 SV1000,2000,3000 S0700(IP40) |
Serial Transmission SystemEX500
Series | Download |
---|---|
EX500 |
|
Serial Transmission System EX510
![]() |
For Input/Output, Gateway Type
∗The applicable protocols differ depending on the series. For details, refer to the catalog of each series. |
Other Data |
---|
Series | Enclosure | Communication protocol∗ | Applicable valve |
---|---|---|---|
EX510 | IP20 |
CC-Link DeviceNet™ PROFIBUS DP EtherNet/IP™ (Made to order) PROFINET (Made to order) |
SJ2000,3000 SY3000,5000,7000 (Plug-in) SY3000,5000,7000,9000 SYJ3000,5000,7000 SQ1000,2000 SZ3000 VQ1000,2000 VQZ1000,2000,3000 S0700 |
Serial Transmission SystemEX510
Series | Download |
---|---|
EX510 |
|
Wireless System EX600-W
![]() |
・Usable even in welding environments
・Noise resistance Uses the 2.4 GHz ISM frequency band Frequency hopping: Every 5 ms ・High-speed connection: From power supply ON to start of communication: Min. 250 ms ・Communication response (Signal response time): 5 ms ・Communication cables not required ・Number of I/O points: Max. 1280 inputs/1280 outputs |
Other Data |
---|
Series | Enclosure | Communication protocol | Applicable valve |
---|---|---|---|
EX600-W | IP67 equivalent |
EtherNet/IP™ PROFINET |
JSY1000, 3000, 5000 (Plug-in) SY3000,5000,7000(Plug-in) SV1000,2000,3000 S0700(IP40) VQC1000,2000,4000,5000 |
Wireless SystemEX600-W
Series | Download |
---|---|
EX600-W |
|
Wireless System Compact Remote EX600-W
![]() |
・Applicable to existing wireless systems
・Compact, Lightweight Area: Approx. 61% reduction∗ (59.8 cm2 ← 155 cm2) Volume: Approx. 86% reduction∗ (159 cm3 ← 1,139 cm3) Weight: Approx. 87% reduction∗ (130 g ← 965 g) ∗ For the e-CON type (Compared with the existing remote, M8 connector/digital 8 inputs specification) |
Other Data |
---|
Series | Enclosure | Communication protocol | Applicable valve |
---|---|---|---|
EX600-W |
e-CON type: IP20 Grommet type: IP67 |
SMC original protocol | Frequency Hopping Spread Spectrum (FHSS) |
Wireless System Compact RemoteEX600-W
Series | Download |
---|---|
EX600-W |
|
M8/M12 Connector PCA/EX9/EX500
![]() |
・Communication cable/connector: CC-Link, DeviceNet™, PROFIBUS DP,
EtherNet/IP™, PROFINET, EtherCAT🄬, Ethernet POWERLINK ・Compliant with IEC61076-2-101 and IEC60947-5-2 Standards ・IP67 (IEC60529) ・Field-wireable connectors: No exclusive tools required, Reduction in wiring time ・SPEEDCON: Just insert the connector and make a 180° rotation. |
Other Data |
---|
Series |
---|
PCA |
EX9 |
EX500 |
M8/M12 ConnectorPCA/EX9/EX500
Series | Download |
---|---|
PCA |
|
EX9 |
|
EX500 |
|
マイリストに追加
フォルダー作成
フォルダー作成
フォルダー名: