HRR Series Thermo-chiller/Rack Mount Type Single-phase 200/230 VAC
Option configuration
Reset
Details
Cooling Capacity
-- Please select --
010(Cooling Capacity Air-cooled:950/1100 W (50/60 Hz);Water-cooled:1000/1100 W (50/60 Hz))
012(Cooling Capacity 1000W/1200W(50/60Hz))
018(Cooling Capacity 1600W/1800W(50/60Hz))
024(Cooling Capacity 2000W/2400W(50/60Hz))
030(Cooling Capacity 2500W/3000W(50/60Hz))
050(Cooling Capacity 4600W/5100W(50/60Hz))
1
Cooling Method
-- Please select --
A(Air-cooled Refrigeration)
W(Water-cooled Refrigeration)
2
Pipe Thread Type
-- Please select --
-(Rc)
F(G (With Rc-G Conversion Fitting Set))
N(NPT (With Rc-NPT Conversion Fitting Set))
3
Power Supply
-- Please select --
20(Single-phase 200 to 230 VAC (50/60 Hz))
4
Option 1
-- Please select --
-(None)
T(High-pressure Pump Mounted)
T1(Inverter Pump Mounted(Pending For UL))
T1U(Inverter Pump Mounted,Conforming To UL Standards)
T1UY(Inverter Pump Mounted,Conforming To UL Standards,With Feet/Without Rack Mounting Brackets)
T1Y(Inverter Pump Mounted,With Feet/Without Rack Mounting Brackets)
TU(High-pressure Pump Mounted,Conforming To UL Standards)
TUY(High-pressure Pump Mounted,Conforming To UL Standards,With Feet/Without Rack Mounting Brackets)
TY(High-pressure Pump Mounted,With Feet/Without Rack Mounting Brackets)
U(Conforming To UL Standards)
UY(Conforming To UL Standards,With Feet/Without Rack Mounting Brackets)
Y(With Feet/Without Rack Mounting Brackets)
DM(With Electric Conductivity Control Function,Applicable To DI Water Piping)
DMT(With Electric Conductivity Control Function,Applicable To DI Water Piping,High-pressure Pump Mounted)
DMT1(With Electric Conductivity Control Function,Applicable To DI Water Piping,Inverter Pump Mounted(Pending For UL))
DMT1U(With Electric Conductivity Control Function,Applicable To DI Water Piping,Inverter Pump Mounted,Conforming To UL Standards)
DMT1UY(With Electric Conductivity Control Function, Applicable To DI Water Piping,Inverter Pump Mounted,Conforming To UL Standards,With Feet/Without Rack Mounting Brackets)
DMT1Y(With Electric Conductivity Control Function, Applicable To DI Water Piping,Inverter Pump Mounted(Pending For UL),With Feet/Without Rack Mounting Brackets)
DMTU(With Electric Conductivity Control Function,Applicable To DI Water Piping,High-pressure Pump Mounted,Conforming To UL Standards)
DMTUY(With Electric Conductivity Control Function, Applicable To DI Water Piping,High-pressure Pump Mounted,Conforming To UL Standards,With Feet/Without Rack Mounting Brackets)
DMTY(With Electric Conductivity Control Function, Applicable To DI Water Piping,High-pressure Pump Mounted,With Feet/Without Rack Mounting Brackets)
DMU(With Electric Conductivity Control Function,Applicable To DI Water Piping,Conforming To UL Standards)
DMUY(With Electric Conductivity Control Function, Applicable To DI Water Piping,Conforming To UL Standards,With Feet/Without Rack Mounting Brackets)
DMY(With Electric Conductivity Control Function, Applicable To DI Water Piping,With Feet/Without Rack Mounting Brackets)
M(Applicable To DI Water (Deionized Water) Piping)
MT(Applicable To DI Water (Deionized Water) Piping,High-pressure Pump Mounted)
MT1(Applicable To DI Water (Deionized Water) Piping,Inverter Pump Mounted(Pending For UL))
MT1U(Applicable To DI Water (Deionized Water) Piping,Inverter Pump Mounted,Conforming To UL Standards)
MT1UY(Applicable To DI Water Piping,Inverter Pump Mounted,Conforming To UL Standards,With Feet/Without Rack Mounting Brackets)
MT1Y(Applicable To DI Water Piping,Inverter Pump Mounted(Pending For UL),With Feet/Without Rack Mounting Brackets)
MTU(Applicable To DI Water (Deionized Water) Piping,High-pressure Pump Mounted,Conforming To UL Standards)
MTUY(Applicable To DI Water Piping,High-pressure Pump Mounted,Conforming To UL Standards,With Feet/Without Rack Mounting Brackets)
MTY(Applicable To DI Water Piping,High-pressure Pump Mounted,With Feet/Without Rack Mounting Brackets)
MU(Applicable To DI Water (Deionized Water) Piping,Conforming To UL Standards)
MUY(Applicable To DI Water Piping,Conforming To UL Standards,With Feet/Without Rack Mounting Brackets)
MY(Applicable To DI Water Piping,With Feet/Without Rack Mounting Brackets)
5
Option 2
-- Please select --
-(None)
Z(Less Option (No Flow Sensor, No Water Leakage Sensor, No Particle Filter, No Bypass Valve, No Retaining Clip))
Z1(Less Option (No Flow Sensor, No Retaining Clip))
6
-- UnSelected
-- Selected
-- Selection invalid