【DO!BOOK・ページリンク】
p-e11-7-25a   119 / 173

BOOKをみる

10秒後にBOOKのページに移動します


ZS 39 5G Vacuum pressure switch assembly 25A ZK2 ZS E A G A q w e r EF V 0 to .101 kPa .100 to 100 kPa .100 to 100 kPa Vacuum pressure switch Pressure switch with energy saving function q Rated pressure range and function AB w Output specifications e Unit specifications Nil M Unit selection function Note 1) SI unit only Note 2) r Lead wire with connector Nil G None With lead wire When q is E or F・・・For vacuum pressure switch, Lead wire with connector (Length 2 m) When q is V・・・For switch with energy saving function, Lead wire with connector (Length 2 m) Note 1) Unit selection function is not available in Japan due to measurement law. Note 2) Fixed unit: kPa Lead wire with connector for vacuum pressure switch (When individual lead wire is necessary, order with the part number below.) !Lead wire with connector for vacuum pressure switch !Lead wire with connector for switch with energy saving function Pressure sensor assembly 25A ZK2 PS A 1 3 0 to .101 kPa, Output: 1 to 5 V, Accuracy: ±2% F.S. or less .100 to 100 kPa, Output: 1 to 5 V, Accuracy: ±2% F.S. or less Rated pressure range and specifications 1 ZK2 LW A 20 A AB NPN open collector PNP open collector Output specifications M Open collector 2 outputs Open collector 1 output NPN PNP Replacement Parts/How to Order 117 Series 25A-ZK2