10秒後にBOOKのページに移動します


Auto switch mounting screw Auto switch Hexagon socket head cap screw (Included with auto switch) (M2.5 x 12 L) Note) Auto switch mounting brackets and auto switches are enclosed with the cylinder for shipment. Applicable Cylinder Series: MGPM-XC88(W), -XC89W, -XC91(W) Applicable auto switches D-M9l/M9lV D-M9lW/M9lWV D-A9l/A9lV D-P3DWA Bore size (mm) o32 to o100 o32 to o100 Auto switch mounting surfaces Surfaces with auto switch mounting slot Surfaces with auto switch mounting slot Mounting of auto switch . When tightening the auto switch mounting screw, use a watchmakers’ screwdriver with a handle 5 to 6 mm in diameter. q Insert the mounting bracket into the mating groove of the cylinder tube. w Check the detecting position of the auto switch and fix the auto switch firmly with the hexagon socket head cap screw (M2.5 x 12 L).* e If the detecting position is changed, go back to step q. Note 1) Ensure that the auto switch is covered with the mating groove to protect the auto switch. Note 2) The tightening torque for the hexagon socket head cap screw (M2.5 x 12 L) is 0.2 to 0.3 N・m. Auto switch model Tightening torque D-M9l(V) D-M9lW(V) 0.05 to 0.15 D-A9l(V) 0.10 to 0.20 Tightening Torque for Auto Switch Mounting Screw Auto Switch Mounting Brackets/Part No. (N・m) MGPM -XC88/XC91 -XC88W/XC89W/XC91W A 60-5