yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz
5-p0021-0067-idfidu_en@@@10 / 50

BOOK‚ð‚Ý‚é

10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚·


Data A: Inlet Air Temperature Correction Factors Data C: Outlet Air Pressure Dew Point Data B: Ambient Temperature Note) Data D: Inlet Air Pressure Data E: Air Flow Capacity Series IDF IDF1E to 75E, 190D to 370D Series IDU IDU3E to IDU37E Correction factor 0.55 0.7 1 1.3 35 10 15 Outlet air pressure dew point (‹C) Correction factor 0.55 0.7 1 1.3 35 10 15 Outlet air pressure dew point (‹C) IDU55E, 75E Correction factor 0.53 0.67 1 1.30 35 10 15 Outlet air pressure dew point (‹C) IDF100F to 150F Correction factor 0.55 0.7 1 1.4 35 10 15 Outlet air pressure dew point (‹C) Series IDF Model IDF1E 0.10 0.12 IDF2E 0.20 0.235 IDF3E 0.32 0.37 IDF4E 0.52 0.57 IDF6E 0.75 0.82 IDF8E 1.22 1.32 IDF11E 1.65 1.82 IDF15E1 2.8 3.1 IDF22E 3.9 4.3 IDF37E 5.7 6.1 IDF55E 8.4 9.8 IDF75E 11.0 12.4 Air flow capacity m3/min (ANR) 50 Hz 60 Hz Series IDU Model IDU3E 0.32 0.37 IDU4E 0.52 0.57 IDU6E 0.75 0.82 IDU8E 1.1 1.2 IDU11E 1.5 1.7 IDU15E1 2.6 2.8 IDU22E 3.9 4.3 IDU37E 5.7 6.1 IDU55E 8.4 9.8 IDU75E 11.0 12.5 Air flow capacity m3/min (ANR) 50 Hz 60 Hz Model IDF125F 20.1 23.7 IDF100F 16.0 18.8 Air flow capacity m3/min (ANR) 50 Hz 60 Hz IDF150F 25.0 30.0 IDF190D 32.0 38.0 IDF240D 43.0 50.0 IDF370D 54.0 65.0 Note) In the case of the option A (cool compressed air output), the air flow capacity is different. Refer to page 49 for details. Series IDF IDF1E to 37E Inlet air temp. (‹C) Correction factor 1.3 1 0.82 0.68 0.57 5 to 30 35 40 45 50 IDF55E, 75E, 190D to 240D Inlet air temp. (‹C) Correction factor 1.35 1.25 1 0.8 0.6 5 to 30 35 40 45 50 IDF100F to 150F Inlet air temp. (‹C) Correction factor 1.41 1.21 1 0.92 0.75 0.63 0.53 5 to 30 35 40 45 50 55 60 Series IDU IDU3E to IDU37E Inlet air temp. (‹C) Correction factor 1.15 1.07 1 0.95 0.9 0.86 0.82 0.79 5 to 45 50 55 60 65 70 75 80 IDF370D Inlet air temp. (‹C) Correction factor 1.25 1.00 0.83 0.70 0.60 5 to 30 35 40 45 50 IDU55E, 75E Inlet air temp. (‹C) Correction factor 1.21 1.10 1 0.87 0.76 0.74 0.72 0.70 5 to 45 50 55 60 65 70 75 80 IDF100F to 150F Ambient temp. (‹C) Correction factor 1.06 1.02 1 0.99 0.98 0.92 2 to 25 30 32 35 40 45 IDF190D to 240D Ambient temp. (‹C) Correction factor 1.10 1.05 1 0.95 0.90 2 to 25 30 32 35 40 IDU55E, 75E Ambient temp. (‹C) Correction factor 1.25 1.11 1 0.90 0.63 2 to 25 30 32 35 40 Series IDF IDF1E to 75E Ambient temp. (‹C) Correction factor 1.14 1.04 1 0.96 0.9 2 to 25 30 32 35 40 Series IDU IDU3E to IDU37E Ambient temp. (‹C) Correction factor 1.2 1.04 1 0.93 0.84 2 to 25 30 32 35 40 Series IDF IDF1E to 75E Inlet air pressure (MPa) Correction factor 0.62 0.72 0.81 0.88 0.95 1 1.06 1.11 1.16 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 to 1.6 IDF190D to 370D Inlet air pressure (MPa) Correction factor 0.68 0.77 0.84 0.90 0.95 1 1.03 1.06 1.08 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 IDF100F to 150F Inlet air pressure (MPa) Correction factor 0.84 0.87 0.9 0.93 0.96 1 1.03 1.06 1.09 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 to 1.6 Series IDU IDU3E to 37E Inlet air pressure (MPa) Correction factor 0.62 0.72 0.81 0.88 0.95 1 1.06 1.11 1.16 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 to 1.6 IDU55E, 75E Inlet air pressure (MPa) Correction factor 0.62 0.69 0.77 0.85 0.93 1 1.08 1.16 1.23 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 to 1.6 Note) For the water-cooled type, the correction factor is determined to g1h in an ambient temperature range of 2 to 45‹C. 27 Model Selection Series IDF/IDU HAA HAW AT IDF IDU IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB ADð® GD