(3) Connect the black and white lead wire pins to the positions shown below in accordance with each kit. 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 Station 1 Black, SOL. A Station 3 Black, SOL. A Station 4 Black, SOL. A Station 5 Black, SOL. A Station 6 Black, SOL. A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 COM. Station 2 Black, SOL. A Station 3 White, SOL. B Station 4 White, SOL. B Station 5 White, SOL. B Wiring (F Kit: D-sub Connector Kit) White Single wiring Double wiring Manifold Specifications’ Example Stations 1 キ 2 キ 3 キ 4 キ 5 キ 6 キ Hook COM (Red) Lead wire assembly Connector terminal no. Black COM (Red) Lead wire assembly Protrusion Station 2 Black, SOL. A Station 3 White, SOL. B Station 4 White, SOL. B Station 5 White, SOL. B 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B 13B Station 1 Black, SOL. A Station 3 Black, SOL. A Station 4 Black, SOL. A Station 5 Black, SOL. A Station 6 Black, SOL. A COM (Red) COM (Red) Wiring (P Kit: Flat Ribbon Cable Kit) Terminal no. Caution Single wiring Double wiring Manifold Specifications’ Example Stations 1 キ 2 キ 3 キ 4 キ 5 キ 6 キ How to Increase Manifold Stations for SQ1000/2000 Black Black Black White Black White Black White Black Red Red 5 stations 3 stations 4 stations 6 stations 2 stations 1 station 1B 1A 2B 2A 3B 3A 4B 4A 5B 13A 13B SOL.A SOL.A SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A COM. COM. Lead wire color Black Black Black White Black White Black White Black Red 5 stations 3 stations 4 stations Terminal no. Lead wire color Terminal no. 6 stations 2 stations 1 station 1 14 2 15 3 16 4 17 5 13 SOL.A SOL.A SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A COM. 1. After inserting the pin, confirm that the pin hook is locked by lightly pulling the lead wire. 2. Do not pull the lead wire forcefully when connecting. Also, take care that lead wires do not get caught between manifolds or when closing the junction cover. Procedure) Based on the manifold specifications, station 1 of SOL.A (black wire) will be terminal number 1 of the D-sub connector, and for station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows. . The drawing above shows connections based on the manifold specifications’ example in the table to the left. . The drawing above shows connections for type 26P flat ribbon cable connector based on the manifold specifications’ example in the table to the left. For type 20P, the connection will be the same as above except that COM changes to 10A and 10B. Plug-in Unit Series SQ1000/2000 Procedure) Based on the manifold specifications, station 1 of SOL.A (black wire) will be terminal number 1B of the flat ribbon cable connector, and for station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows. 1389 SY SJ SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ VFS VFR VQ7 SQ