Terminal screw Tightening torque 0.25 to 0.35 N・m Connect the round terminal of the red lead wire to the common terminal inside the junction cover. (1) Connecting common terminals Connect lead wire assemblies included with manifold blocks as follows. (2) Pulling out connector Pull out the connector to connect the lead wire. . For F, P, and J kits, pull out and remove the housing while pressing down hard on the hook with a flat head screwdriver, etc. Remove the manual lever and lead wire cover, and pull out the connector. . For T kits, remove the screws and pull out the terminal block. . For S kits, remove the screws and pull out the connector. 3. Connection Method (Refer to page 1386 regarding the steps for adding stations to a manifold block.) F, P, J kit T kit S kit Screw (Tightening torque 0.8 to 1.0 N・m) Screw (Tightening torque 0.14 to 0.17 N・m) Housing  Hook Housing (F kit) (P, J kit) Connector Manual lever Remove the stopper and pull out the connector. Spring Protrusion Lead wire cover Hook Terminal block How to Increase Manifold Stations for SQ1000/2000 F, P, J kit T, S kit Series SQ1000/2000 Connector 1388