【DO!BOOK・ページリンク】
1-p1329-1451-sq1000_en   114 / 125

BOOKをみる

10秒後にBOOKのページに移動します


How to Increase Manifold Stations for SQ1000/2000 2. Connection Method Housing (F kit) (P, J kit) Connector Manual lever Spring Protrusion Housing cover Slot Stopper Connector to be added White (SOL. B) Black (SOL. A) Socket Red (COM wire) Steps for adding stations q Loosen the clamp screw on the U side end plate and open the manifold. w Mount the manifold block or valve with manifold block to be added. e Press on the end plate to eliminate any space between the manifold blocks and tighten the clamp screw. (Proper tightening torque: 0.8 to 1.0 N・m) r In the case of F kit, P kit or J kit, remove the connector housing from the DIN rail and connect the wiring. (1) Connecting common wire Insert the red lead wire (common wire) of the connector to be added into the adjacent connector as shown in the drawing below. After inserting, lightly pull on the wire to confirm that the socket is locked. (2) Pulling out connector Pull out the connector to connect the lead wires for SOL. A and SOL. B. Insert a flat head screwdriver into the slot of the housing cover and remove it. Remove the manual lever and pull out the connector. F, P, J kit r q q e e w Connector housing (F kit is shown.) D side U side Connector Remove the stopper and pull out the connector. Series SQ1000/2000 1440