Since connected equipment will operate when the manual override is activated, confirm that conditions are safe prior to activation. Push type (tool required) is standard, and locking type (tool required) is optional. Cylinder port fittings are available in cassette type and can be replaced easily. Fittings are secured with a retaining clip that is inserted from the top side of the valve. After removing the valve,remove the clip with a flat head screw driver to replace the fittings. To mount a fitting, insert the fitting assembly until it stops and reinsert the retaining clip to its designated position. Warning Caution Proper tightening torque (N・m) 0.8 to 1.2 Push type (Tool required) Locking type (Tool required)