【DO!BOOK・ページリンク】
1-p1153-1215-vqc1000_en   39 / 64

BOOKをみる

10秒後にBOOKのページに移動します


1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM T Station 1 Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 Station 8 Station 9 Station 10 Series VQC1000/2000 Kit (Terminal block box) . This kit has a small terminal block inside a junction box. The electrical entry port of a G 3/4 permits connection of conduit fittings. . Applicable crimped terminal: 1.25-3S,1.25Y-3,1.25Y-3N,1.25Y-3.5 . Name plate: VVQ5000-N-T . Drip-proof plug assembly (for G 3/4): AXT100-B06A Terminal Block Connection Proper tightening torque (N・m) 0.7 to 1.2 Step 3. Mounting the terminal block cover Securely tighten the screws to the torque shown in the table below, after confirming that the gasket is installed correctly. Step 1. Removing the terminal block cover Loosen the 4 mounting screws (M4) and remove the terminal block cover. Step 2. The diagram below shows the terminal block wiring. All stations are provided with double wiring regardless of the valves which are mounted. Connect each wire to the power supply side, according Mounting screw (M4) to the markings provided inside the terminal block. Terminal block cover Gasket Electrical entry 2 x G 3/4 M3 screw 6 mm Electrical Wiring Specifications (IP67 compatible) Note) When using the negative COM specification, use valves for negative COM. Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring are available as an option. 1A (.) (+) 1B (.) (+) 2A (.) (+) 2B (.) (+) 3A (.) (+) 3B (.) (+) 4A (.) (+) 4B (.) (+) 5A (.) (+) 5B (.) (+) 6A (.) (+) 6B (.) (+) 7A (.) (+) 7B (.) (+) 8A (.) (+) 8B (.) (+) 9A (.) (+) 9B (.) (+) 10A (.) (+) 10B (.) (+) (+) (.) Terminal no. Polarity Positive COM spec. Negative COM spec. COM Standard wiring Note) Special Wiring Specifications (Option) Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed 20. 1. How to Order Indicate option symbol “-K” in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet. 2. Wiring specifications Connector terminal numbers are connected from solenoid station 1 on the A side in the order indicated by the arrows without skipping any terminal numbers. IP67 compliant SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B SOL.A 1190 Series VQC